| Proximity Sensors |
| E2C-T:
Type: Inductive Max Response Frequency:1 kHz Max Sensing
Distance: 20mm Enclosure Rating: IP67 |
| E2E Cylindrical Proximity
Sensor: Type:Inductive Max Response Frequency:
3 KHz Max. Sensing Distance: 20mm Enclosure Rating: IP67
|
| E2E-L:Compact,
Thin Model Ensure Ease of Use |
  |
| Click
here for sample applications |
| |
| E2C-T |
| Proximity Sensor with Separate
Amplifier Unit and Teaching Function for Precise
Sensitivity Adjustment |
|
|
| Features (You
may click on some of the images below for larger
view) |
| Three
teaching modes allow easy setup |
 |
| Three types
of teaching (i.e., teaching with and
without a sensing object, teaching without
sensing object, and positioning teaching)
ensure easy sensitivity adjustment. |
| |
|
| Can
be used with many existing sensor |
 |
| In
addition to the pillar type of the conventional
E2C sensor heads M8, 5.4 dia., M5, 3.8
dia., and 3.5 dia., and the sensor head
of 2 dia. is also lineup. A sensor cord
can be cut into the optimal length.(Except
E2C-CR5B2) |
| |
|
| 10-mm-wide,
slim Amplifier Unit. |
 |
| The width
of amplifier is 10mm (14mm of conventional
models), and it contributes to space
saving. The E2C-T16 is a new product
that incorporates a connector and connects
to the Sensor Terminals for CompoBus/S
use. |
|
| Application
Examples |
 |
| |
| Dimensions |
 |
 |
| |
| Specifications |
|
Sensors |
| Item
Model |
E2C-CR5B2 |
E2C-CR8A
E2C-CR8B
|
E2C-X1A
E2C-C1A
|
E2C-X1R5A |
| Stable
sensing range (within whole rated
temperature range) |
0
to 0.5 mm |
0 to 0.8 mm |
0 to 1 mm |
0 to 1.5 mm |
| Stable
sensing range at 0°C to 40°C |
0
to 0.7 mm |
0
to 1.2 mm |
0
to 1.5 mm |
0
to 2 mm |
| Sensing
object |
Ferrous
metal (Sensitivity lowers with
non-ferrous metals) |
| Standard
sensing object |
Iron,
5 × 5 × 1 mm |
Iron,
8 × 8 × 1 mm |
| Response
frequency*1 |
1
kHz |
800
Hz |
| Ambient
temperature |
Operating/Storage:
-10°C
to 55°C
|
Operating:
-25°C to 70°C |
|
(with
no icing or condensation) |
| Ambient
humidity |
Operating/Storage:
35% to 95%RH (with no condensation) |
| Temperature
influence |
±25%
max. of sensing distance
at
23°C in the temperature range
of -10°C to 55°C |
±15%
max. of sensing distance at 23°C
in temperature range of -25°C
to 70°C |
| Vibration
resistance |
10
to 55 Hz, 1.5-mm double amplitude
for 2 hours each in X, Y, and
Z directions |
| Shock
resistance |
Destruction:
500 m/s² for 3 times each in X,
Y, and Z directions |
| Protective
structure |
IEC60529
IP64 |
IEC60529
IP67 |
| Connection
method |
Pre-wired
models (shielded cable: 3 m only) |
Pre-wired
models (high frequency coaxial
cable;standard length: 2 m) *2 |
| Weight
(Packed state) |
Approx.
10 g |
Approx.40g |
Approx.
45 g |
Approx.
50 g |
| Material |
Case |
Stainless
steel |
Brass |
| Sensing
surface |
ABS |
| Cable |
Polyethylene |
|
|
|
Amplifier
Unit |
| Item
Model |
E2C-CR5B2 |
E2C-CR8A/-CR8B |
E2C-X1A/-C1A |
E2C-X1R5A |
|
Rated supply voltage (operating voltage)
|
12 to 24 VDC 10% with a ripple (p-p)
of 10% max.
|
| Current
consumption |
50
mA max. |
| Sensing
distance adjustment range*1 |
Setting distance for teaching without
sensing object |
0.4 mm min.
|
0.72 mm min. |
0.9 mm min. |
0.35 mm min. |
|
Setting distance for teaching with and
without sensing object or positioning
teaching |
0°C to 40°C |
0.1 to 0.7 mm
|
0.16 to 1.2 mm |
0.2 to 1.5 mm |
0.3 to 2 mm |
|
0°C to 55°C |
0.1 to 0.5 mm |
0.16 to 0.8 mm |
0.2 to 1.0 mm |
0.3 to 1.5 mm |
| Differential
distance |
15%
max. of sensing distance |
10%
max. |
| Response
time |
Refer
to the response frequency of the Proximity
Sensor in use. |
| Control
output |
NPN
open collector 100 mA max. (under 30
VDC) (residual voltage 1 V max.)
|
| Operating
status |
NO/NC
selectable |
| Indicator
lamp |
Operation
indicator (orange) and stability indicator
(green) |
| Cord
length compensation |
3
m only |
1,
2, or 3 m selectable |
| Ambient
temperature |
Operating/Storage:
0°C to 55°C (with no icing or condensation)
|
| Ambient
humidity |
Operating/Storage:
35% to 95%RH (with no condensation)
|
| Temperature
influence |
±25%
max. of sensing distance at 23°C in
the temperature range of 0°C to 55°C
|
±10%
max. of sensing distance at 23°C in
the temperature range of 0°C to 55°C
|
| Voltage
influence |
1%
max. of sensing distance within a range
of 90% to 110% of the rated power supply
voltage. |
| Insulation
resistance |
50
M
!&
min.
(at 500 VDC) between current carry parts
and case |
| Dielectric
strength |
1000
VAC 50/60 Hz for 1 min between current
carrying part and case |
| Vibration
resistance |
Destruction:
10 to 55 Hz, 1.5-mm double amplitude
for 2 hours each in X, Y, and Z directions
|
| Shock
resistance |
Destruction:
500 m/s² for 10 times each in X, Y,
and Z directions |
| Protective
structure |
IEC
60529 IP50 |
| Connection
method |
Pre-wired
type (Standard length: 3 m) |
| Weight
(Packed state) |
Approx.
70 g |
| Accessories |
Mounting
bracket, instruction manual |
|
| |
| E2E
Cylindrical Proximity Sensor |
| Easy-to-use and
tough |
 |
|
- Wide range of models
- Ideal for a variety
of applications
- With a metal connector
that can be tightened securely and
a cord protector
- With an easy-to-se
indicator, deeper mounting holes,
and tightening flats for wrenches
- The new series
of E2E models includes M8 plug-in
connector models.
- Enclosure rating
of IP67, water-proof and oil-drip
proof
|
|
| Specifications |
|
Model
|
E2E Cylindrical
Proximity Sensor
|
|
Dimensions
|
Dia
4 x 25 mm, M5 x 25 mm
Dia
5.4 x 25 mm, M8 x 36 mm
M12
x 33 mm, M18 x 38 mm, M30 x 43 mm
|
|
Sensing
Distance
|
0.8
mm, 1 mm, 1.5 mm, 2 mm, 3 mm, 4 mm,
5 mm, 7 mm, 8 mm, 10 mm, 14 mm, 18
mm, 20 mm (± 10%)
|
|
Supply
voltage
|
12
to 24 VDC (-20%
+ 60%)
24
to 240 VAC (15% + 10%)
|
|
Power
(current) Consumption
|
0.8
~ 17 mA max.
|
|
Control
Output
|
|
|
Response
Frequency
|
25
Hz to 3 kHz
|
|
Ambieut
Operating Temperature
|
-25
to 70ºC or -40 to 85ºC
|
|
Weight
(approx)
|
45
to 270 g
|
|
Enclosure
Ratings
|
IEC
IP67
|
|
Approved
Standards/Markings
|
EN/IEC,
CE
|
|
| |
| E2E-L |
| Compact, Thin
Model Ensure Ease of Use |
 |
|
- DC 3 wire connection.
- Standard CELENEC
body.
- Operation mode
NO.
- Current consumption:
< 15mA max.
- Power supply voltage:
10 - 35 VDC.
- Enclosure rating:
IP67.
- Ambient temperature:
-25 to 70°C.
- Many models available.
|
|
| |
| Few
Sample Applications: |
 |
 |
| Checking
robot hand gripping (Very small cylindrical
proximity sensor) |
Welding
Line |
 |
 |
| Detecting
robot origin and limit |
Machine
dog detection |
 |
|
| Detecting
the position |
|
|
|
|
|
|
|