FEP & PFA Burst Pressure Calculations

Formulas for the approximate burst pressure of tubings over temperature.

Approximate PFA 451 tube burst pressure value may be calculated by the following formula:

BP=[2278-(3.77)(T)][(OD/ID)-1]


NOTE: This formula is only valid for temperatures "T" between 0F and 500F.

Approximate FEP tube burst pressure value may be calculated by the following formula:

BP=[1929-(4.29)(T)][(OD/ID)-1]


NOTE: This formula is only valid for temperatures "T" between 0F and 500F.

For further information, please contact NetMotion, Inc. at 1.800.790.7837 or e-mail sales@netmotion.com